| Model | CL-3000 | |
| Type | Controller | |
| Number of optical unit connections | Controller only: 2 units; using expansion units/relay units: 6 units | |
| Interface | EtherNet/IPTM | Supports cyclic communication and message communication; RPI: 1 to 10,000 ms (0.5 ms units) Maximum number of connections: 8, complies with Version.CT14 conformance test PROFINET and PLC-Link cannot be used in conjunction with EtherNet/IPTM |
| PROFINET | Compatible with conformance class A. EtherNet/IPTM and PLC-Link cannot be used in conjunction with PROFINET | |
| PLC-Link | The following PLCs are supported: Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series EtherNet/IPTM and PROFINET cannot be used in conjunction with PLC-Link |
|
| Ethernet | Allows for measurement data output and control I/O via no-protocol command communication with PCs and PLCs 100Base-TX, capable of communication with CL-NavigatorN |
|
| USB | Conforms to USB 2.0 HighSpeed, capable of communication with CL-NavigatorN | |
| RS-232C | Allows for measurement data output and control I/O via no-protocol command communication with PCs and PLCs Baud rate: 9600 to 115,200 bps, data length: 8 bit, stop bit: 1 bit, parity: none/even numbers/odd numbers |
|
| Terminal (IN) | 13 (supports function switching via software) | |
| Terminal (OUT) | 11*1 (supports function switching via software) | |
| Ratings | Power voltage | 24 VDC ±10% |
| Maximum current consumption | With 1 optical unit connected: 0.86 A, with 4 optical units connected: 3.3 A, with 6 optical units connected: 4.5 A | |
| Environmental resistance | Operating ambient temperature | 0 to 50°C |
| Operating ambient humidity | 20% RH to 85% RH (no condensation) | |
| Vibration resistance | 10 to 57 Hz, double amplitude 0.3 mm; 2 hours each for X, Y, and Z axes | |
| Monitor/Setting support software | CL-NavigatorN | |
| Weight | Approx. 600 g | |
| CL-NavigatorN OS environment | Supported OS | Windows® 10 *2 / Windows® 7 *3 |
| CPU | Celeron Dualcore 1.7 GHz or higher | |
| Memory capacity | 4 GB or more | |
| Required free space on hard disk | 1 GB or more | |
| Display resolution | XGA (1024 x 768 pixels) or higher | |
| *1 Positive common connection is supported for NPN input devices, and negative common connection for PNP input devices. *2 Home, Pro and Enterprise Editions are supported. *3 Home Premium, Professional and Ultimate Editions are supported. •Windows® and Excel are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. |