Main controller: Built-in type, PNP

  • Описание
  • Получить КП
Описание
Model LK-G5001PV*1*2
Separate type LK-G5001P/LK-HD500
Type Main controller
Sensor head compatibility Compatible
No. of connectable sensor heads 2
Display Minimum display unit LK-HD500: 0.001 µm
Display range LK-HD500: ±999.999 µm to ±9,999.99 mm (7 settings selectable)
Display cycle LK-HD500: Approx. 10 times/sec.
Display interface Display port Either the display unit (LK-HD500) or dedicated touch panel (LK-HD1001) can be connected
LED indicator LASER ON
Terminal block Analogue output voltage ±10 V output, Output impedance: 100 ?
Analogue current output 4 to 20 mA, Maximum load resistance: 350 ?
No. of analogue outputs 2
TIMING 1 input Voltage input*3
RESET 1 input
Auto-zero 1 input
Laser control input Voltage input*4
Laser remote input Non-voltage input
Alarm output PNP open-collector output
General comparator output
Expansion connector TIMING input Voltage input
RESET input
Auto-zero input
Program switching input
Binary selection input
Alarm output PNP open-collector output
Comparator output
Binary output
RS-232C interface Baud rate: 9,600 to 115,200 bps
Data length: 8 bits, Stop bit length: 1 bit, Parity: None/even/odd
USB interface USB 2.0 Hi-Speed compliant*5
Ethernet interface 100Base-TX/10Base-T*6
EtherNet/IPTMinterface Cyclic communication (implicit messaging)
Message communication (explicit messaging) : UCMM and Class3
Number of connections: 32
Complies with conformance test version CT14*7
PLC-Link The following PLCs are supported:Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series
EtherNet/IPTM, CC-Link, and DeviceNetTM cannot be used in conjunction with PLC-Link
Head expansion unit connector Up to 10 head expansion units can be connected to one main controller
Expansion unit connector Either of the CC-Link unit (LK-CC100) or DeviceNetTM unit (LK-DN100) can be connected
Power supply Power supply voltage 24 VDC ±10 %
Maximum current consumption 0.6 A or less with 1 head/3.5 A or less with 12 heads
Environmental resistance Ambient temperature When one or less head expansion unit is connected: 0 to +50 °C.
When two or more head expansion units are connected: 0 to +40 °C.
Relative humidity 35 to 85 % RH (No condensation)
Weight Approx. 600 g
*1 PNP open-collector output rating: 50 mA max. (30 V max.), Residual voltage: 0.5 V max.
Voltage input rating: Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA
*2 Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to “Precautions on wiring” in the User’s Manual.
*3 This input is applied to all of the synchronized OUT.
*4 When the laser class 3B sensor head is connected, a key-operated switch must be used for the input to this terminal. The laser is emitted only when the key-operated switch is set to the ON position. (Select a key which can be removed only when it is set to the OFF position.)
When the laser class 1/2/3R sensor head is connected, the laser turns on when this terminal is opened and turns off when it is short-circuited.
*5 When a PC supporting USB 1.1 or USB 2.0 full speed is connected, the data refresh cycle and other operations may slow down.
*6 Use the Ethernet interface only for direct connections with a PC or for local network connections with a PC or LK-G5000 Series units.
*7 The EtherNet/IPTM interface cannot be used when a CC-Link unit or a DeviceNetTM unit is installed.
EtherNet/IPTM is supported by the latest controllers. For details on which controllers support EtherNet/IPTM , contact your nearest KEYENCE office.
Получить КП
Для получения коммерческого предложения, пожалуйста, вышлите ваш запрос на электронную почту info@keyence-datchiki.ru с указанием требуемых позиций и реквизитами компании.
Категория: Датчики измерения

Похожие товары

Датчик Keyence OP-76876
Закрыть

Датчик измерения Keyence OP-76876

Fixing bracket to fix panel amplifier (1 pc.)
Quick View
Датчик Keyence GT-H22
Закрыть

Датчик измерения Keyence GT-H22

Sensor Head
Quick View
Датчик Keyence OP-77680
Закрыть

Датчик измерения Keyence OP-77680

Contact, Roller Type
Quick View
Датчик Keyence OP-26751
Закрыть

Датчик измерения Keyence OP-26751

End unit (2 pcs.)
Quick View
Датчик Keyence GT-75A
Закрыть

Датчик измерения Keyence GT-75A

Amplifier Unit, Panel Mount Type, NPN
Quick View
Датчик Keyence GT-H22L
Закрыть

Датчик измерения Keyence GT-H22L

Sensor Head, Low Measuring Force Type
Quick View
Датчик Keyence GT-76A
Закрыть

Датчик измерения Keyence GT-76A

Amplifier Unit, Panel Mount Type, NPN
Quick View
Датчик Keyence GT-A22L
Закрыть

Датчик измерения Keyence GT-A22L

Sensor Head, Low Measuring Force Type, Air Cylinder Model
Quick View

Официальный сайт дилера Keyence в России. Поставки полного каталога Keyence с доставкой по территории всей России. Обеспечим Вам честные цены, гибкие условия оплаты и официальную поставку.

Москва, Михалковская улица, 63б
Тел: +7 (499) 346-62-38
Emai: info@keyence-datchiki.ru
Права на все торговые марки и изображения на данном сайте принадлежат KEYENCE CORPORATION
закрыть
Start typing to see products you are looking for.
  • Главная
  • О компании
  • Каталог
  • Новости
  • Контакты
Scroll To Top