Model | FS-M2 | |
Type | 1-line expansion unit | |
Output | NPN | |
Light source | Red LED | |
Sensitivity adjustment/Mode selection | 8-turn trimmer (with indicator), FINE/TURBO (switch-selectable) | |
Response time | 250 µs (FINE) /500 µs (TURBO) | |
Operation mode | LIGHT-ON/DARK-ON (switch-selectable) | |
Indicator lamp | Output: Red LED Stable operation: Green LED |
|
Timer function | ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable) | |
Input | ? | |
Control output | NPN: 100 mA (40 V) max. Residual voltage: 1 V max.*1 |
|
Stability output | NPN open-collector 50 mA max. (40 VDC max.), Residual voltage: 1 V max.*2 | |
Protection circuit | Reversed polarity protection, Overcurrent protection, Surge absorber | |
Unit expansion | Up to 16 expansion units can be connected (a total of 17 units)*3 | |
Mutual interference suppression | FINE : 4, TURBO/SUPER: 8 | |
Rating | Power voltage | 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less*4 |
Current consumption | 35 mA or less | |
Environmental resistance | Ambient light | Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max. |
Ambient temperature | -10 to +55 °C (No freezing)*5 | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |
Case material | Polycarbonate | |
Weight | Approx. 40 g | |
*1 La salida de alarma de interrupcion de conexion no esta disponible en ES-M2 (P). *2 Only the FS-T1 and FS-M1 can provide stability outputs. *3 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less. 3 to 10 Units: -10 to +50°C (14 to 122°F), 11 to 16 Units: -10 to +45°C (14 to 113°F) *4 Power to the FS-T2/T0/M2/M0 is supplied through the FS-T1/M1/V1/V11/R0, PS-T1, LV-21A/11A or CZ-V1. *5 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is 20 mA or less. When extended |
Датчик Keyence FS-M2
Fibre Amplifier, Cable Type, Expansion Unit, NPN
Описание
Получить КП
Для получения коммерческого предложения, пожалуйста, вышлите ваш запрос на электронную почту [email protected] с указанием требуемых позиций и реквизитами компании.
Категория: Датчики