| Model | LR-ZB100C3P*1 | |
| Type | Distance based laser sensor | |
| Shape | Rectangular | |
| Output | PNP | |
| Cable connection | M8 connector, 3-pin | |
| Detectable distance | 35 to 100 mm (650 to 0)*2 | |
| Standard detectable deviation | 35 to 50 mm: 1.5 mm 50 to 100 mm: 3 mm |
|
| Display resolution | 2 (0.2 mm) | |
| Spot diameter | Approx. 2 ? 1 mm at 100 mm | |
| Response time | 1.5 ms / 10 ms / 50 ms selectable | |
| Light source | Type | Red laser (660 nm) |
| Laser class | Class 1 laser product (IEC60825-1, FDA (CDRH) Part1040.10*3) |
|
| Function | Indicator | 3-digit 7-segment display (red), output indicator (yellow), DATUM indicator (orange), 1 spot indicator (green) |
| Timer | OFF/ON delay/OFF delay/One-shot | |
| Rating | Power voltage | 10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
| Power consumption | 450 mW or less (18 mA or less at 24 V, 34 mA or less at 12V) | |
| Specifications | Control output | PNP Open collector, Applied voltage 30 VDC or less, Control current 100 mA or less, Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA |
| Protection circuit | Protection against reverse power connection, output overcurrent, output surge, reverse output connection | |
| Output operation | Light-ON / Dark-ON selectable | |
| Environmental resistance | Enclosure rating | IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*4, Diversey*4 |
| Insulation resistance | 20 M? or more (500 VDC) | |
| Ambient light | Incandescent lamp: 4,000 lux or less Sunlight: 8,000 lux or less*5 |
|
| Ambient temperature | -10 to +50 °C (No freezing) | |
| Storage temperature | -25 to +75 °C (No freezing) | |
| Relative humidity | 35 to 85 % RH (No condensation) | |
| Withstand voltage | 1,000 VAC, 50/60 Hz, 1 min | |
| Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
| Shock resistance | 1,000 m/s2, 6 times in each of the X, Y, and Z directions | |
| Material | Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating, Packing/Connector ring: FKM |
|
| Accessories | Instruction Manual, Certification/Identification label (FDA) |
|
| Weight | Approx. 55 g | |
| *1 M8 connector (3-pin) type does not include the external input function. *2 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds “-99”, “-FF” is displayed. *3 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *4 Have passed resistance tests with cleaning agents from multiple manufactures. *5 When the response time is 10 ms |