Model | EX-V05E | |
Type | Controller | |
Shape | o14.5 x 20 mm Cylindrical,threaded | |
Measuring range | 0 to 5 mm | |
A/D converting system | Sequential conversion | |
Display range | -19999 to +19999 | |
Linearity | ±0.3% of F.S. | |
Resolution (No. of averaging measurements: 64) |
2 µm | |
Sampling rate | 40000 samplings max./sec. *1 | |
Display speed | 20 times/second | |
Display power | 7-segment 2-colour LED | |
Over-range alarm | ±FFFF is displayed. | |
Control input | Timing input | NPN open-collector or non-voltage contact signal |
Reset input | ||
Auto-zero input | ||
Judgment output: Inhibit input | ||
Synchronization/external settings input | ||
Controloutput | Setting method | Upper/lower 2-level setting x 4 patterns (selectable) |
Control output | Signal | NPN open-collector (HIGH, GO and LOW): 100 mA max. (40 V max.) |
Controloutput | Response time | 0.075 ms (at maximum speed) |
OFF-delay time | 60 ms (ON/OFF selectable) | |
Strobe output | NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.O.) | |
Control output | Alarm output | NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.C.) |
Analogue output voltage | Output voltage | ±0.5 V |
Impedance | 100 ? | |
Response time | 0.075 ms (at maximum speed) | |
Temperature characteristics | 0.07% of F.S./°C *2 | |
Major functions | FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. | |
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less |
Current consumption | 240 mA or less | |
Environmental resistance | Ambient temperature | 0 to +50 °C |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Weight | Approx. 235 g | |
*1 When the digital filter function is used, the sampling rate is 20000 sampling/sec. *2 When the distance between the sensor head and the target is within 50% of the measuring range. |
Датчик измерения Keyence EX-V05E
Amplifier Unit NPN
Описание
Получить КП
Для получения коммерческого предложения, пожалуйста, вышлите ваш запрос на электронную почту [email protected] с указанием требуемых позиций и реквизитами компании.
Категория: Датчики измерения