| Model | EX-V05P*1 | |
| Type | Amplifier Unit PNP | |
| Shape | o14.5 x 20 mm Cylindrical,threaded | |
| Measuring range | 0 to 5 mm | |
| A/D converting system | ? | |
| Display range | -19999 to +19999 | |
| Linearity | ±0.3% of F.S. | |
| Resolution (No. of averaging measurements: 64) |
1 µm | |
| Sampling rate | 40000 samplings max./sec. *2 | |
| Display speed | 20 times/second | |
| Display power | 7-segment 2-colour LED | |
| Over-range alarm | ±FFFF is displayed. | |
| Control input | Timing input | 10 to 30 V is applied. |
| Reset input | ||
| Auto-zero input | ||
| Judgment output: Inhibit input | ||
| Synchronization/external settings input | ||
| Control output | PNP: Applied voltage; 10 to 30 V | |
| Controloutput | Setting method | Upper/lower 2-level setting x 4 patterns (selectable) |
| Control output | Signal | PNP open-collector (HIGH, GO and LOW): 100 mA max. (30 V max.) |
| Controloutput | Response time | 0.075 ms (at maximum speed) |
| OFF-delay time | 60 ms (ON/OFF selectable)*3 | |
| Strobe output | PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.) | |
| Control output | Alarm output | PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.) |
| Analogue output voltage | Output voltage | ±5V |
| Impedance | 100 ? | |
| Response time | 0.075 ms (at maximum speed) | |
| Temperature characteristics | 0.07% of F.S./°C *4 | |
| Major functions | FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. | |
| Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less |
| Current consumption | 240 mA or less | |
| Environmental resistance | Ambient temperature | 0 to +50 °C |
| Relative humidity | 35 to 85 % RH (No condensation) | |
| Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
| Weight | Approx. 235 g | |
| *1 The above data was obtained using an iron target (S45C, SS400, t=1 mm). When measuring aluminium, copper, or stainless steel targets, refer to the linear characteristics for these materials. *2 When the digital filter function is used, the sampling rate is 20000 sampling/sec. *3 NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP output converter. *4 When the distance between the sensor head and the target is within 50% of the measuring range. |
Датчик измерения Keyence EX-V05P
Amplifier Unit PNP
Описание
Получить КП
Для получения коммерческого предложения, пожалуйста, вышлите ваш запрос на электронную почту info@keyence-datchiki.ru с указанием требуемых позиций и реквизитами компании.
Категория: Датчики измерения