Model | EX-V02P*1 | |
Type | Amplifier Unit PNP | |
Shape | M10 x 18 mm Threaded | |
Measuring range | 0 to 2 mm | |
A/D converting system | ? | |
Display range | -19999 to +19999 | |
Linearity | ±0.3% of F.S. | |
Resolution (No. of averaging measurements: 64) |
0.4 µm | |
Sampling rate | 40000 samplings max./sec. *2 | |
Display speed | 20 times/sec. | |
Display power | 7-segment 2-colour LED | |
Over-range alarm | ±FFFF is displayed. | |
Control input | Timing input | 10 to 30 V is applied. |
Reset input | ||
Auto-zero input | ||
Judgment output: Inhibit input | ||
Synchronization/external settings input | ||
Control output | PNP: Applied voltage; 10 to 30 V | |
Controloutput | Setting method | Upper/lower 2-level setting x 4 patterns (selectable) |
Control output | Signal | PNP open-collector (HIGH, GO and LOW): 100 mA max. (30 V max.) |
Controloutput | Response time | 0.075 ms (at maximum speed) |
OFF-delay time | 60 ms (ON/OFF selectable) | |
Strobe output | PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.) | |
Control output | Alarm output | PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.) |
Analogue output voltage | Output voltage | ±5V |
Impedance | 100 ? | |
Response time | 0.075 ms (at maximum speed) | |
Temperature characteristics | 0.07% of F.S./°C *3 | |
Major functions | FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. | |
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less |
Current consumption | 240 mA or less | |
Environmental resistance | Ambient temperature | 0 to +50 °C |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Weight | Approx. 235 g | |
*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm). When measuring aluminium, copper, or stainless steel targets, refer to the linear characteristics for these materials. *2 When the digital filter function is used, the sampling rate is 20000 sampling/sec. *3 When the distance between the sensor head and the target is within 50% of the measuring range. |