Датчик Keyence IX-1000
ГлавнаяДатчики Датчик Keyence IX-1000
Previous product
Датчик идентификации Keyence OP-M1902
Датчик Keyence OP-87716
Back to products
Next product
Датчик Keyence IX-055
Датчик Keyence IX-055

Датчик Keyence IX-1000

Sensor Amplifier Main unit

  • Описание
  • Получить КП
Описание
Model IX-1000
Main unit / expansion unit Main unit
Display Min. display unit 10 µm*1
Display range ±999.99 to ±999 mm (with 4 selectable steps)*1
Tools Scan mode Height, Height difference, Max./Min., Height difference calculation, Thickness calculation, Height detection, Monochromatic detection, Position adjustment
(Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool*2
Line mode Height (Ave./Max./Min.), Height difference (Ave./Max./Min.), Height difference calculation, Thickness calculation, Position adjustment, Tilt correction
(Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool, Alignment adjustment: 1 tool*2
Other functions Common ZERO/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, Zero/offset recording, Capture mode (HDR) Sensor date/time Information addition, N.O./N.C. switching, I/O monitor, Automatic brightness adjustment, Lighting (ON/OFF), Total judgement conditions, NPN/PNP switching, Simultaneous main unit/expansion unit input, Light interference prevention, Security
Scan mode Measurement range, Measurement position (small/standard/large), Measurement mode, Measurement noise elimination, Imaging mode (high gain), Tilt correction (fixed or real-time correction), Glare removal, Trigger input (internal/external), Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Fixed reference area, Mask outline, Rotation range
Line mode Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.)
Input Non-voltage input/voltage input is switchable
For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)
Input Number of inputs 8 (IN1 to IN8)
Function IN1: External trigger up/down timing, IN2 to IN8: Enable by assigning optional functions
Assignable functions: Program switching, Laser emission stop, Zero/offset (batch), Reset (error only), Reset (judgement value only) Reset (judgement value and error)
Output Open collector output; NPN/PNP switchable, N.O./N.C. switchable
For open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 1.5 V or less
For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 2 V or less
Output Number of outputs 10 (OUT1 to OUT10)
Function Enable by assigning the optional functions
Assignable functions: Total judgement result (All OK, Any OK/NG), run, busy, error, position adjustment result, tilt correction result,
Monochromatic detection / Height detection tool result (OK/NG), Height / height difference / Max./Min. / calculation tool result (OK/NG/HIGH/LO), Alarm
Analogue voltage output ±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 ?*3
Analogue current output 4 to 20 mA, max. load resistance: 350 ?*3
Number of programs 32
Statistical information Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)
Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) *1*4
Detection history Saved history 100*5
Save conditions Selectable from NG only / All*5
Ethernet Standard 100BASE-TX/10BASE-T*6
Connector RJ45 8-pin connector*6
Interface compatibility CC-Link / DeviceNetTM / EtherNet/IPTM / EtherCAT? / RS-232C / BCD / PROFINET / PROFIBUS / TCP/IP output*7
Number of connectible units Main units: 1, Expansion units: 1, Communication units (DL): 1
Ratings Power voltage 24 VDC ±10% (including ripple)
Current consumption Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load) *8
Environmental resistance Operating ambient temperature 0 to +50°C (No freezing)
Operating ambient humidity 35 to 85% RH (No condensation)
Material Main unit case: PC / Power connector: PA, POM / Analogue output connector: PA, POM / I/O connector: PA /
Head connector: Zinc + Ni plating, PA/Ethernet connector: Copper alloy + Ni plating / Rear heat sink: Aluminium /
Main unit rear DIN rail fixing tab: POM / Nameplate: PC
Weight Approx. 210 g
*1 For displaying on an IX Series control panel or PC software.
*2 Configurable for each program.
*3 Select ±5 V, 1 to 5 V, 0 to 5 V, or 4 to 20 mA for use.
*4 When sample hold (edge), peak/bottom/P-P hold (level/edge) is set.
*5 Saves to the sensor amplifier’s internal memory. Detection history saved inside the sensor amplifier can be backed up to a PC using the USB memory stick connected to the IX Series control panel or PC software.
*6 For connection to an IX Series control panel or PC software. The RJ45 connector on the main unit is used for connecting to the expansion unit.
*7 When a DL Series device is used. Contact KEYENCE for information on other interfaces.
*8 Includes a DL Series communication unit.
Получить КП
Для получения коммерческого предложения, пожалуйста, вышлите ваш запрос на электронную почту [email protected] с указанием требуемых позиций и реквизитами компании.
Категория: Датчики

Похожие товары

Датчик Keyence FS2-62
Закрыть

Датчик Keyence FS2-62

Fibre Amplifier, Cable Type, NPN
Quick View
Датчик идентификации Keyence OP-M1902
Закрыть

Датчик Keyence FS-16G

Amplifier Unit
Quick View
Датчик идентификации Keyence OP-M1902
Закрыть

Датчик Keyence FS-15G

Amplifier Unit
Quick View
Датчик Keyence FS-14
Закрыть

Датчик Keyence FS-14

Fibre Amplifier NPN
Quick View
Датчик Keyence FS2-62P
Закрыть

Датчик Keyence FS2-62P

Fibre Amplifier, Cable Type, PNP
Quick View
Датчик идентификации Keyence OP-M1902
Закрыть

Датчик Keyence OP-6025

FS2 Mounting Bracket
Quick View
Датчик идентификации Keyence OP-M1902
Закрыть

Датчик Keyence FS-16IR

Amplifier Unit
Quick View
Датчик Keyence Multi-Purpose CCD Laser Micrometer
Закрыть

Датчик Keyence Multi-Purpose CCD Laser Micrometer

IG series
Quick View

Официальный сайт дилера Keyence в России. Поставки полного каталога Keyence с доставкой по территории всей России. Обеспечим Вам честные цены, гибкие условия оплаты и официальную поставку.

Москва, Михалковская улица, 63б
Тел: +7 (499) 346-62-38
Emai: [email protected]
Права на все торговые марки и изображения на данном сайте принадлежат KEYENCE CORPORATION
закрыть
Start typing to see products you are looking for.
  • Главная
  • О компании
  • Каталог
  • Новости
  • Контакты
Scroll To Top