| Model | LV-11SA | ||
| Type | Main unit | ||
| Main unit/Expansion unit | |||
| Applicable model | LV-S61/S41/S41L/S31/S71/S72 | ||
| Control output | NPN open-collector ? 2 channels, 40 VDC maximum, 100 mA or less per output | ||
| Response time | ExceptLV-S31 | ULTRA | 4 ms |
| SUPER | 2 ms | ||
| TURBO | 500 µs | ||
| FINE | 250 µs | ||
| HSP | 80 µs | ||
| LV-S31standard mode | 500 µs | ||
| LV-S31standard mode | SPED2 | 2 ms | |
| SPED3 | 8 ms | ||
| SPED4 | 32 ms | ||
| LV-S31High-speed mode | 250 µs | ||
| Control input | Light emission stop input, external calibration, set value bank selection input, or received light intensity shift input | ||
| Number of interference prevention units | ULTRA | ? | |
| SUPER | |||
| TURBO | |||
| FINE | |||
| HSP | |||
| Unit expansion | |||
| Rating | Power voltage | 12 to 24 VDC, Ripple (P-P) 10 % or less, Class 2*1 | |
| Power consumption | Normal | 1.5 W or less (62.5 mA or less at 24 V) | |
| Ratings | Eco-Half Eco-All | 1.35 W or less (57.3 mA or less at 24 V) | |
| Environmental resistance | Ambient temperature | -10 to +55 °C (No freezing)*2 | |
| Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis | ||
| Material | Main unit | Main body, cover: Polycarbonate | |
| Weight | Approx. 80 g (including 2 m cable) | ||
| *1 When more than 8 units connected, be sure to use supply voltage 24 VDC Ripple (P-P) 10 % max. *2 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows: 1 to 2 units connected: -10 to +55 °C, 3 to 10 units connected: -10 to +50 °C, 11 to 16 units connected: -10 to +45 °C |
Датчик Keyence LV-11SA