Model | GP-M010 | |
Rated pressure | -0.1 to +1 MPa (-1 to +10 bar) |
|
Possible display range | -0.210 to +1.110 MPa (-2.10 to +11.10 bar) |
|
Zero-cut pressure value | ±0.5% of F.S. | |
Burst pressure | 15 MPa (150 bar) | |
Display resolution | 0.001 MPa (0.01 bar) | |
Fluid type | Gas or liquid that will not corrode the liquid contact part | |
Type of pressure | Gage pressure | |
Precision | ±1.0% of F.S. or less*1 | |
Repeatability | ±0.3% of F.S. or less*2 | |
Temperature characteristics | ±0.6% of F.S./10°C | |
Connection diameter | G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.) | |
Box rotation angle | Maximum 330° | |
Medium temperature | -20 to +100°C (no freezing/condensation)*3 | |
Power supply voltage | 10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS | |
Current consumption | 50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4 | |
Display method | 4 column, digital LED, red/Vertical inversion display possible | |
Operation display light | Operation indicator (output 1) (orange), Operation indicator (output 2) (orange) | |
Hysteresis | During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis) During window mode: fixed (0.5% of F.S.) |
|
Response | Control output | Selectable from 3 to 5000 ms |
Analogue output | As above + 2 ms (90% response) | |
Output | Output 1 control output | NPN/PNP open collector (Selectable), Max. 250 mA (30 V max) Main unit residual voltage 1 V max, N.O./N.C. selectable |
Output 2 replacement type |
Control output | |
Analogue output | 4-20 mA, maximum load resistance 500 ? (When the electric voltage is more than 20 V)*5 | |
Environmental resistance | Enclosure rating | IP67 |
Pressure resistance | 4 MPa (40 bar) | |
Ambient temperature | -20 to +80 °C (No freezing and no condensation) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axes) | |
Shock resistance | IEC60068-2-27 50G (11 ms, 3 times for each of X, Y and Z direction) | |
Material properties |
Port/diaphragm | Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM |
Other parts | Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole: PTFE, nickel-plated brass. | |
Applicable cable | M12 connector 4 pin | |
Weight | Approx. 150 g | |
*1 This is the value when considering linearity + hysterisis + repeatability in a stable environment of 23°C. *2 The repeatability, based on consistent conditions, is the difference in the detection points at the time of fluctuations in the repetition. *3 When the temperature of the piping exceeds 80°C, do not connect the cable. *4 Consumption current including output is 0.6 A and under. *5 The maximum load resistance R will be the values below in response to the electric voltage E. When 10-23V: R = {38 x (E-10) + 128} ? When 23-30V: R = 622 ? |
Датчик процесса Keyence GP-M010
Main Unit, Positive-pressure Type, 1 MPa
Описание
Получить КП
Для получения коммерческого предложения, пожалуйста, вышлите ваш запрос на электронную почту [email protected] с указанием требуемых позиций и реквизитами компании.
Категория: Датчики процесса